# Calibrations

Default calibration macros provided by DyzeDesign.

# C29 - Mesh scan calibration

Command: C29

Calibration to call G29 and display the scan progress

# C32 - Bed Tilt Calibration

Command: C32

Calibration wizard that calls G32 to probe the bed, compensates for bed tilt, and displays the probed points and resulting Z motor adjustments.

# M712 - Input shaping calibration

Command: M712

Interactive 4-step calibration wizard using an accelerometer to measure X and Y axis resonance frequencies and compare shaper algorithms and damping factors.

# M762 - Pressure advance calibration

Command: M762

Interactive calibration wizard that prints test lines across a range of pressure advance K coefficients (M572) to help identify and refine the optimal value.

  • T: Tool number to calibrate (optional)

# M763 - PID Autotune - Single heater

Command: M763

Interactive calibration wizard to run PID autotuning (M303) on a single heater at a specified target temperature and PWM limit. Results are automatically applied to the settings.

  • H: Heater identifier (moduleId-port) to tune (optional)

# M764 - PID Autotune - Tool

Command: M764

Interactive calibration wizard to run multi-pass PID autotuning (M303) across all heaters of a selected tool. Results are automatically applied to the settings

  • T: Tool number to tune (optional)