# Calibrations
Default calibration macros provided by DyzeDesign.
# C29 - Mesh scan calibration
Command: C29
Calibration to call G29 and display the scan progress
# C32 - Bed Tilt Calibration
Command: C32
Calibration wizard that calls G32 to probe the bed, compensates for bed tilt, and displays the probed points and resulting Z motor adjustments.
# M712 - Input shaping calibration
Command: M712
Interactive 4-step calibration wizard using an accelerometer to measure X and Y axis resonance frequencies and compare shaper algorithms and damping factors.
# M762 - Pressure advance calibration
Command: M762
Interactive calibration wizard that prints test lines across a range of pressure advance K coefficients (M572) to help identify and refine the optimal value.
- T: Tool number to calibrate (optional)
# M763 - PID Autotune - Single heater
Command: M763
Interactive calibration wizard to run PID autotuning (M303) on a single heater at a specified target temperature and PWM limit. Results are automatically applied to the settings.
- H: Heater identifier (
moduleId-port) to tune (optional)
# M764 - PID Autotune - Tool
Command: M764
Interactive calibration wizard to run multi-pass PID autotuning (M303) across all heaters of a selected tool. Results are automatically applied to the settings
- T: Tool number to tune (optional)