# Axis Settings
# Axis
Selects the logical printer axis this axis configuration controls.
| Property | Value |
|---|---|
| Required | Yes |
| Type | string |
| Default | `` |
| Allowed values | X, Y, Z, U, V, W, A, B, C |
# Endstop
Selects the endstop input used to detect when the axis reaches its limit of travel. Endstop can be specified either in the axis configuration to apply to all motors of the axis, or in the motor configuration to apply to a specific motor.
| Property | Value |
|---|---|
| Required | No |
| Type | string or null |
| Default | null |
| Allowed values | Base: X1, X2, Y1, Y2, Z1, Z2, Z prob1, Z prob2Dynamic: Accessories whose type is Bed Sensor with a Laser sensor type. |
# Endstop input type
Indicates whether the endstop input is normally open/closed.
| Property | Value |
|---|---|
| Required | No |
| Type | boolean |
| Default | false |
# Endstop offset
Coordinate offset applied when the axis reaches its endstop.
| Property | Value |
|---|---|
| Required | Yes |
| Type | number |
| Default | 0 |
# Minimum
Minimum coordinate value allowed for this axis.
| Property | Value |
|---|---|
| Required | Yes |
| Type | number |
| Default | 0 |
# Maximum
Maximum coordinate value allowed for this axis.
| Property | Value |
|---|---|
| Required | Yes |
| Type | number |
| Default | null |
| Limits / format | maximum: 500000 |
# Motors
References the motors that move this axis.
| Property | Value |
|---|---|
| Required | Yes |
| Type | array |
| Default | [] |
| Limits / format | minimum items: 1; items: string |
# Endstop position
Specifies whether the axis endstop is located at the start or end of travel.
| Property | Value |
|---|---|
| Required | No |
| Type | string or null |
| Default | null |
| Allowed values | Start, End, null |