# Tool Settings

# Pulsar

# Tool number

Numeric identifier used to select this tool in G-code.

Property Value
Required Yes
Type integer
Default null
Limits / format minimum: 0

# Name

User-defined name for this tool.

Property Value
Required No
Type string
Default ``

# X real axis (for IDEX architecture)

Logical axis used as this tool's X coordinate reference.

Property Value
Required No
Type string
Default X
Allowed values X, Y, Z, U, V, W, A, B, C

# Y real axis (for IDEX architecture)

Logical axis used as this tool's Y coordinate reference.

Property Value
Required No
Type string
Default Y
Allowed values X, Y, Z, U, V, W, A, B, C

# Z real axis (for IDEX architecture)

Logical axis used as this tool's Z coordinate reference.

Property Value
Required No
Type string
Default Z
Allowed values X, Y, Z, U, V, W, A, B, C

# X offset

Tool offset from the machine origin along the X axis.

Property Value
Required No
Type number
Default 0

# Y offset

Tool offset from the machine origin along the Y axis.

Property Value
Required No
Type number
Default 0

# Z offset

Tool offset from the machine origin along the Z axis.

Property Value
Required No
Type number
Default 0

# Motor

References the motor that drives this tool.

Property Value
Required Yes
Type string
Default null

# Temperature setpoints

Preset temperatures values for the control slider.

Property Value
Required No
Type array
Default []
Limits / format items: number; item minimum: 0

# Fan

References the fan used to cool this tool.

Property Value
Required No
Type string or null
Default null

# Fan act. temp

Tool temperature above which the assigned fan is activated.

Property Value
Required No
Type number or null
Default null

# Part cooling fan

References the fan used to cool printed material.

Property Value
Required No
Type string or null
Default null

# Water cooling

References the liquid-cooling accessory assigned to this tool.

Property Value
Required No
Type string or null
Default null

# Water cool act. temp.

Tool temperature above which liquid cooling is activated.

Property Value
Required No
Type number or null
Default null

# Low extrusion speed

Slow speed used for manual extrusion operations in the control interface.

Property Value
Required Yes
Type number
Default 5
Limits / format minimum: 1; maximum: 1000

# High extrusion speed

Fast speed used for manual extrusion operations.

Property Value
Required Yes
Type number
Default 60
Limits / format minimum: 1; maximum: 1000

# Pressure compensation K coefficient

Pressure advance coefficient used to compensate for extrusion pressure changes.

Property Value
Required Yes
Type number
Default 0
Limits / format minimum: 0; maximum: 1

# Top heater

References the heater assigned to the top heating zone of this tool.

Property Value
Required Yes
Type string
Default null

# Middle heater

References the heater assigned to the middle heating zone of this tool.

Property Value
Required Yes
Type string
Default null

# Bottom heater

References the heater assigned to the bottom heating zone of this tool.

Property Value
Required Yes
Type string
Default null

# Pressure sensor

References the pressure sensor assigned to this tool.

Property Value
Required No
Type string or null
Default null
Allowed values Dynamic: Accessories whose type is Load Cell.

# Pellets feeding system

References the pellet feeding system assigned to this tool.

Property Value
Required No
Type string or null
Default null

# DyzEnd

# Tool number

Numeric identifier used to select this tool in G-code.

Property Value
Required Yes
Type integer
Default null
Limits / format minimum: 0

# Name

User-defined name for this tool.

Property Value
Required No
Type string
Default ``

# X real axis (for IDEX architecture)

Logical axis used as this tool's X coordinate reference.

Property Value
Required No
Type string
Default X
Allowed values X, Y, Z, U, V, W, A, B, C

# Y real axis (for IDEX architecture)

Logical axis used as this tool's Y coordinate reference.

Property Value
Required No
Type string
Default Y
Allowed values X, Y, Z, U, V, W, A, B, C

# Z real axis (for IDEX architecture)

Logical axis used as this tool's Z coordinate reference.

Property Value
Required No
Type string
Default Z
Allowed values X, Y, Z, U, V, W, A, B, C

# X offset

Tool offset from the machine origin along the X axis.

Property Value
Required No
Type number
Default 0

# Y offset

Tool offset from the machine origin along the Y axis.

Property Value
Required No
Type number
Default 0

# Z offset

Tool offset from the machine origin along the Z axis.

Property Value
Required No
Type number
Default 0

# Motor

References the motor that drives this tool.

Property Value
Required Yes
Type string
Default null

# Temperature setpoints

Preset temperatures values for the control slider.

Property Value
Required No
Type array
Default []
Limits / format items: number; item minimum: 0

# Fan

References the fan used to cool this tool.

Property Value
Required No
Type string or null
Default null

# Fan act. temp

Tool temperature above which the assigned fan is activated.

Property Value
Required No
Type number or null
Default null

# Part cooling fan

References the fan used to cool printed material.

Property Value
Required No
Type string or null
Default null

# Water cooling

References the liquid-cooling accessory assigned to this tool.

Property Value
Required No
Type string or null
Default null

# Water cool act. temp.

Tool temperature above which liquid cooling is activated.

Property Value
Required No
Type number or null
Default null

# Low extrusion speed

Slow speed used for manual extrusion operations in the control interface.

Property Value
Required Yes
Type number
Default 5
Limits / format minimum: 1; maximum: 1000

# High extrusion speed

Fast speed used for manual extrusion operations.

Property Value
Required Yes
Type number
Default 60
Limits / format minimum: 1; maximum: 1000

# Pressure compensation K coefficient

Pressure advance coefficient used to compensate for extrusion pressure changes.

Property Value
Required Yes
Type number
Default 0
Limits / format minimum: 0; maximum: 1

# Heater

References the heater assigned to this tool.

Property Value
Required Yes
Type string
Default null

# Filament size

Diameter of the filament used by the tool, in millimetres.

Property Value
Required No
Type number
Default 2.85
Allowed values 1.75, 2.85

# Filament monitor

References the filament monitor assigned to this tool.

Property Value
Required No
Type string or null
Default null

# Typhoon

# Tool number

Numeric identifier used to select this tool in G-code.

Property Value
Required Yes
Type integer
Default null
Limits / format minimum: 0

# Name

User-defined name for this tool.

Property Value
Required No
Type string
Default ``

# X real axis (for IDEX architecture)

Logical axis used as this tool's X coordinate reference.

Property Value
Required No
Type string
Default X
Allowed values X, Y, Z, U, V, W, A, B, C

# Y real axis (for IDEX architecture)

Logical axis used as this tool's Y coordinate reference.

Property Value
Required No
Type string
Default Y
Allowed values X, Y, Z, U, V, W, A, B, C

# Z real axis (for IDEX architecture)

Logical axis used as this tool's Z coordinate reference.

Property Value
Required No
Type string
Default Z
Allowed values X, Y, Z, U, V, W, A, B, C

# X offset

Tool offset from the machine origin along the X axis.

Property Value
Required No
Type number
Default 0

# Y offset

Tool offset from the machine origin along the Y axis.

Property Value
Required No
Type number
Default 0

# Z offset

Tool offset from the machine origin along the Z axis.

Property Value
Required No
Type number
Default 0

# Motor

References the motor that drives this tool.

Property Value
Required Yes
Type string
Default null

# Temperature setpoints

Preset temperatures values for the control slider.

Property Value
Required No
Type array
Default []
Limits / format items: number; item minimum: 0

# Fan

References the fan used to cool this tool.

Property Value
Required No
Type string or null
Default null

# Fan act. temp

Tool temperature above which the assigned fan is activated.

Property Value
Required No
Type number or null
Default null

# Part cooling fan

References the fan used to cool printed material.

Property Value
Required No
Type string or null
Default null

# Water cooling

References the liquid-cooling accessory assigned to this tool.

Property Value
Required No
Type string or null
Default null

# Water cool act. temp.

Tool temperature above which liquid cooling is activated.

Property Value
Required No
Type number or null
Default null

# Low extrusion speed

Slow speed used for manual extrusion operations in the control interface.

Property Value
Required Yes
Type number
Default 5
Limits / format minimum: 1; maximum: 1000

# High extrusion speed

Fast speed used for manual extrusion operations.

Property Value
Required Yes
Type number
Default 60
Limits / format minimum: 1; maximum: 1000

# Pressure compensation K coefficient

Pressure advance coefficient used to compensate for extrusion pressure changes.

Property Value
Required Yes
Type number
Default 0
Limits / format minimum: 0; maximum: 1

# Top heater

References the heater assigned to the top heating zone of this tool.

Property Value
Required Yes
Type string
Default null

# Bottom heater

References the heater assigned to the bottom heating zone of this tool.

Property Value
Required Yes
Type string
Default null

# Filament size

Diameter of the filament used by the tool, in millimetres.

Property Value
Required No
Type number
Default 2.85
Allowed values 1.75, 2.85

# Filament monitor

References the filament monitor assigned to this tool.

Property Value
Required No
Type string or null
Default null

# Atom

# Tool number

Numeric identifier used to select this tool in G-code.

Property Value
Required Yes
Type integer
Default null
Limits / format minimum: 0

# Name

User-defined name for this tool.

Property Value
Required No
Type string
Default ``

# X real axis (for IDEX architecture)

Logical axis used as this tool's X coordinate reference.

Property Value
Required No
Type string
Default X
Allowed values X, Y, Z, U, V, W, A, B, C

# Y real axis (for IDEX architecture)

Logical axis used as this tool's Y coordinate reference.

Property Value
Required No
Type string
Default Y
Allowed values X, Y, Z, U, V, W, A, B, C

# Z real axis (for IDEX architecture)

Logical axis used as this tool's Z coordinate reference.

Property Value
Required No
Type string
Default Z
Allowed values X, Y, Z, U, V, W, A, B, C

# X offset

Tool offset from the machine origin along the X axis.

Property Value
Required No
Type number
Default 0

# Y offset

Tool offset from the machine origin along the Y axis.

Property Value
Required No
Type number
Default 0

# Z offset

Tool offset from the machine origin along the Z axis.

Property Value
Required No
Type number
Default 0

# Motor

References the motor that drives this tool.

Property Value
Required Yes
Type string
Default null

# Temperature setpoints

Preset temperatures values for the control slider.

Property Value
Required No
Type array
Default []
Limits / format items: number; item minimum: 0

# Fan

References the fan used to cool this tool.

Property Value
Required No
Type string or null
Default null

# Fan act. temp

Tool temperature above which the assigned fan is activated.

Property Value
Required No
Type number or null
Default null

# Part cooling fan

References the fan used to cool printed material.

Property Value
Required No
Type string or null
Default null

# Water cooling

References the liquid-cooling accessory assigned to this tool.

Property Value
Required No
Type string or null
Default null

# Water cool act. temp.

Tool temperature above which liquid cooling is activated.

Property Value
Required No
Type number or null
Default null

# Low extrusion speed

Slow speed used for manual extrusion operations in the control interface.

Property Value
Required Yes
Type number
Default 5
Limits / format minimum: 1; maximum: 1000

# High extrusion speed

Fast speed used for manual extrusion operations.

Property Value
Required Yes
Type number
Default 60
Limits / format minimum: 1; maximum: 1000

# Pressure compensation K coefficient

Pressure advance coefficient used to compensate for extrusion pressure changes.

Property Value
Required Yes
Type number
Default 0
Limits / format minimum: 0; maximum: 1

# Top heater

References the heater assigned to the top heating zone of this tool.

Property Value
Required Yes
Type string
Default null

# Bottom heater

References the heater assigned to the bottom heating zone of this tool.

Property Value
Required Yes
Type string
Default null

# Pressure sensor

References the pressure sensor assigned to this tool.

Property Value
Required No
Type string or null
Default null
Allowed values Dynamic: Accessories whose type is Load Cell.

# Pellets feeding system

References the pellet feeding system assigned to this tool.

Property Value
Required No
Type string or null
Default null

# Zephyr

# Tool number

Numeric identifier used to select this tool in G-code.

Property Value
Required Yes
Type integer
Default null
Limits / format minimum: 0

# Name

User-defined name for this tool.

Property Value
Required No
Type string
Default ``

# X real axis (for IDEX architecture)

Logical axis used as this tool's X coordinate reference.

Property Value
Required No
Type string
Default X
Allowed values X, Y, Z, U, V, W, A, B, C

# Y real axis (for IDEX architecture)

Logical axis used as this tool's Y coordinate reference.

Property Value
Required No
Type string
Default Y
Allowed values X, Y, Z, U, V, W, A, B, C

# Z real axis (for IDEX architecture)

Logical axis used as this tool's Z coordinate reference.

Property Value
Required No
Type string
Default Z
Allowed values X, Y, Z, U, V, W, A, B, C

# X offset

Tool offset from the machine origin along the X axis.

Property Value
Required No
Type number
Default 0

# Y offset

Tool offset from the machine origin along the Y axis.

Property Value
Required No
Type number
Default 0

# Z offset

Tool offset from the machine origin along the Z axis.

Property Value
Required No
Type number
Default 0

# Motor

References the motor that drives this tool.

Property Value
Required Yes
Type string
Default null

# Temperature setpoints

Preset temperatures values for the control slider.

Property Value
Required No
Type array
Default []
Limits / format items: number; item minimum: 0

# Fan

References the fan used to cool this tool.

Property Value
Required No
Type string or null
Default null

# Fan act. temp

Tool temperature above which the assigned fan is activated.

Property Value
Required No
Type number or null
Default null

# Part cooling fan

References the fan used to cool printed material.

Property Value
Required No
Type string or null
Default null

# Water cooling

References the liquid-cooling accessory assigned to this tool.

Property Value
Required No
Type string or null
Default null

# Water cool act. temp.

Tool temperature above which liquid cooling is activated.

Property Value
Required No
Type number or null
Default null

# Low extrusion speed

Slow speed used for manual extrusion operations in the control interface.

Property Value
Required Yes
Type number
Default 5
Limits / format minimum: 1; maximum: 1000

# High extrusion speed

Fast speed used for manual extrusion operations.

Property Value
Required Yes
Type number
Default 60
Limits / format minimum: 1; maximum: 1000

# Pressure compensation K coefficient

Pressure advance coefficient used to compensate for extrusion pressure changes.

Property Value
Required Yes
Type number
Default 0
Limits / format minimum: 0; maximum: 1

# Heater

References the heater assigned to this tool.

Property Value
Required Yes
Type string
Default null

# Filament size

Diameter of the filament used by the tool, in millimetres.

Property Value
Required No
Type number
Default 1.75
Allowed values 1.75, 2.85

# Filament monitor

References the filament monitor assigned to this tool.

Property Value
Required No
Type string or null
Default null

# Zephyr Early Access

# Tool number

Numeric identifier used to select this tool in G-code.

Property Value
Required Yes
Type integer
Default null
Limits / format minimum: 0

# Name

User-defined name for this tool.

Property Value
Required No
Type string
Default ``

# X real axis (for IDEX architecture)

Logical axis used as this tool's X coordinate reference.

Property Value
Required No
Type string
Default X
Allowed values X, Y, Z, U, V, W, A, B, C

# Y real axis (for IDEX architecture)

Logical axis used as this tool's Y coordinate reference.

Property Value
Required No
Type string
Default Y
Allowed values X, Y, Z, U, V, W, A, B, C

# Z real axis (for IDEX architecture)

Logical axis used as this tool's Z coordinate reference.

Property Value
Required No
Type string
Default Z
Allowed values X, Y, Z, U, V, W, A, B, C

# X offset

Tool offset from the machine origin along the X axis.

Property Value
Required No
Type number
Default 0

# Y offset

Tool offset from the machine origin along the Y axis.

Property Value
Required No
Type number
Default 0

# Z offset

Tool offset from the machine origin along the Z axis.

Property Value
Required No
Type number
Default 0

# Motor

References the motor that drives this tool.

Property Value
Required Yes
Type string
Default null

# Temperature setpoints

Preset temperatures values for the control slider.

Property Value
Required No
Type array
Default []
Limits / format items: number; item minimum: 0

# Fan

References the fan used to cool this tool.

Property Value
Required No
Type string or null
Default null

# Fan act. temp

Tool temperature above which the assigned fan is activated.

Property Value
Required No
Type number or null
Default null

# Part cooling fan

References the fan used to cool printed material.

Property Value
Required No
Type string or null
Default null

# Water cooling

References the liquid-cooling accessory assigned to this tool.

Property Value
Required No
Type string or null
Default null

# Water cool act. temp.

Tool temperature above which liquid cooling is activated.

Property Value
Required No
Type number or null
Default null

# Low extrusion speed

Slow speed used for manual extrusion operations in the control interface.

Property Value
Required Yes
Type number
Default 5
Limits / format minimum: 1; maximum: 1000

# High extrusion speed

Fast speed used for manual extrusion operations.

Property Value
Required Yes
Type number
Default 60
Limits / format minimum: 1; maximum: 1000

# Pressure compensation K coefficient

Pressure advance coefficient used to compensate for extrusion pressure changes.

Property Value
Required Yes
Type number
Default 0
Limits / format minimum: 0; maximum: 1

# Spindle

# Tool number

Numeric identifier used to select this tool in G-code.

Property Value
Required Yes
Type integer
Default null
Limits / format minimum: 0

# Name

User-defined name for this tool.

Property Value
Required No
Type string
Default ``

# X real axis (for IDEX architecture)

Logical axis used as this tool's X coordinate reference.

Property Value
Required No
Type string
Default X
Allowed values X, Y, Z, U, V, W, A, B, C

# Y real axis (for IDEX architecture)

Logical axis used as this tool's Y coordinate reference.

Property Value
Required No
Type string
Default Y
Allowed values X, Y, Z, U, V, W, A, B, C

# Z real axis (for IDEX architecture)

Logical axis used as this tool's Z coordinate reference.

Property Value
Required No
Type string
Default Z
Allowed values X, Y, Z, U, V, W, A, B, C

# X offset

Tool offset from the machine origin along the X axis.

Property Value
Required No
Type number
Default 0

# Y offset

Tool offset from the machine origin along the Y axis.

Property Value
Required No
Type number
Default 0

# Z offset

Tool offset from the machine origin along the Z axis.

Property Value
Required No
Type number
Default 0

# Module IO

Identifier of the IO module that controls this tool.

Property Value
Required Yes
Type integer
Default null

# Port

Port number on the selected module used by this device.

Property Value
Required Yes
Type integer
Default 7
Allowed values 7

# Max RPM

Maximum spindle speed in revolutions per minute.

Property Value
Required Yes
Type integer
Default 25000
Limits / format minimum: 1; maximum: 100000

# Wait for stable

Waits for the spindle speed to stabilize before continuing.

Property Value
Required No
Type boolean
Default true

# Custom Tool

Custom tool with no predefined behaviour or required properties.

# Tool number

Numeric identifier used to select this tool in G-code.

Property Value
Required Yes
Type integer
Default null
Limits / format minimum: 0

# Name

User-defined name for this tool.

Property Value
Required No
Type string
Default ``

# X real axis (for IDEX architecture)

Logical axis used as this tool's X coordinate reference.

Property Value
Required No
Type string
Default X
Allowed values X, Y, Z, U, V, W, A, B, C

# Y real axis (for IDEX architecture)

Logical axis used as this tool's Y coordinate reference.

Property Value
Required No
Type string
Default Y
Allowed values X, Y, Z, U, V, W, A, B, C

# Z real axis (for IDEX architecture)

Logical axis used as this tool's Z coordinate reference.

Property Value
Required No
Type string
Default Z
Allowed values X, Y, Z, U, V, W, A, B, C

# X offset

Tool offset from the machine origin along the X axis.

Property Value
Required No
Type number
Default 0

# Y offset

Tool offset from the machine origin along the Y axis.

Property Value
Required No
Type number
Default 0

# Z offset

Tool offset from the machine origin along the Z axis.

Property Value
Required No
Type number
Default 0

# Motor

References the motor that drives this tool.

Property Value
Required No
Type string or null
Default null

# Temperature setpoints

Preset temperatures values for the control slider.

Property Value
Required No
Type array
Default []
Limits / format items: number; item minimum: 0

# Fan

References the fan used to cool this tool.

Property Value
Required No
Type string or null
Default null

# Fan act. temp

Tool temperature above which the assigned fan is activated.

Property Value
Required No
Type number or null
Default null

# Part cooling fan

References the fan used to cool printed material.

Property Value
Required No
Type string or null
Default null

# Water cooling

References the liquid-cooling accessory assigned to this tool.

Property Value
Required No
Type string or null
Default null

# Water cool act. temp.

Tool temperature above which liquid cooling is activated.

Property Value
Required No
Type number or null
Default null

# Low extrusion speed

Slow speed used for manual extrusion operations in the control interface.

Property Value
Required No
Type number
Default 5
Limits / format minimum: 1; maximum: 1000

# High extrusion speed

Fast speed used for manual extrusion operations.

Property Value
Required No
Type number
Default 60
Limits / format minimum: 1; maximum: 1000

# Pressure compensation K coefficient

Pressure advance coefficient used to compensate for extrusion pressure changes.

Property Value
Required No
Type number
Default 0
Limits / format minimum: 0; maximum: 1

# Number of Heaters

Number of heaters configured for this custom tool.

Property Value
Required No
Type integer
Default 1
Allowed values 1, 2, 3

# Filament size

Diameter of the filament used by the tool, in millimetres.

Property Value
Required No
Type number
Default 2.85
Allowed values 1.75, 2.85

# Filament monitor

References the filament monitor assigned to this tool.

Property Value
Required No
Type string or null
Default null

# Single Heater

# Heater

References the heater assigned to this tool.

Property Value
Required No
Type string or null
Default null

# Dual Heater

# Top heater

References the heater assigned to the top heating zone of this tool.

Property Value
Required No
Type string or null
Default null

# Bottom heater

References the heater assigned to the bottom heating zone of this tool.

Property Value
Required No
Type string or null
Default null

# Triple Heater

# Top heater

References the heater assigned to the top heating zone of this tool.

Property Value
Required No
Type string or null
Default null

# Middle heater

References the heater assigned to the middle heating zone of this tool.

Property Value
Required No
Type string or null
Default null

# Bottom heater

References the heater assigned to the bottom heating zone of this tool.

Property Value
Required No
Type string or null
Default null