# Heater Settings
# Name
User-defined name for this heater.
| Property | Value |
|---|---|
| Required | No |
| Type | string |
| Default | `` |
# Heater number
Optional numeric identifier used to address this heater. Use when Heater number mode for M104/109 is enabled.
| Property | Value |
|---|---|
| Required | No |
| Type | number or null |
| Default | null |
# Module ID
Identifier of the IO module that controls this heater.
| Property | Value |
|---|---|
| Required | Yes |
| Type | integer |
| Default | null |
# Port
Port number on the selected module used by this device.
| Property | Value |
|---|---|
| Required | Yes |
| Type | integer |
| Default | null |
| Allowed values | 0, 1, 2, 3, 4, 5, 6, 7 |
# Temperature limit
Maximum temperature allowed for this heater, in degrees Celsius.
| Property | Value |
|---|---|
| Required | Yes |
| Type | number |
| Default | 500 |
| Limits / format | minimum: 0 |
# Pwm limit
Maximum PWM output allowed for this heater, expressed as an integer percentage.
| Property | Value |
|---|---|
| Required | Yes |
| Type | number |
| Default | 100 |
| Limits / format | minimum: 0; maximum: 100 |
# Sensor type
Selects the sensor technology or electrical behavior for this device. Possible values: 'Temperature' Custom Sensors + ["Thermistor_300","Thermistor_500","PT100"]
| Property | Value |
|---|---|
| Required | Yes |
| Type | string |
| Default | null |
| Allowed values | Base: Thermistor_300, Thermistor_500, PT100Dynamic: Custom sensors whose type is Temperature. |
# P
Proportional gain of the heater or servo PID controller.
| Property | Value |
|---|---|
| Required | Yes |
| Type | number |
| Default | 0 |
# I
Integral gain of the heater or servo PID controller.
| Property | Value |
|---|---|
| Required | Yes |
| Type | number |
| Default | 0 |
# D
Derivative gain of the heater or servo PID controller.
| Property | Value |
|---|---|
| Required | Yes |
| Type | number |
| Default | 0 |
# PID Temperature
Only used to document the temperature at which the PID values were tuned. It does not affect the PID controller operation.
| Property | Value |
|---|---|
| Required | No |
| Type | number |
| Default | 0 |
# X Min
Used for smart bed. Mininum X coordinate affected by this heater.
| Property | Value |
|---|---|
| Required | No |
| Type | number or null |
| Default | null |
# Y Min
Used for smart bed. Mininum Y coordinate affected by this heater.
| Property | Value |
|---|---|
| Required | No |
| Type | number or null |
| Default | null |
# X Max
Used for smart bed. Maximum X coordinate affected by this heater.
| Property | Value |
|---|---|
| Required | No |
| Type | number or null |
| Default | null |
# Y Max
Used for smart bed. Maximum Y coordinate affected by this heater.
| Property | Value |
|---|---|
| Required | No |
| Type | number or null |
| Default | null |